M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.2
Technical specications and illustrations are without
obligation, subject to modications. 03.97/06.06
Probe series SP
®
non heated basis version SP 10 heated basis version SP 10-H
Part Number 01 S 1000 01 S 2000
Dust load max.10 g/m
3
* optional >10g/m
3
Sample pressure 0.4 to 6 bar abs*
Ambient temperature -20 °C to +60 °C**
Insitu probe length 270 mm*, optional with extension tube up to 2000 mm
Sample temperature V10 max. 600 °C*, optional HC max. 900 °C
Mounting flange DN65 PN6, Form B, SS 316Ti
Sample gas outlet connection 1/8"-NPT internal, for tube connectors max. ø10 mm
Filter element without volume displacer V10, filter porosity 2 µm, SS 316 -ø46 mm x 225 mm
Material of sample contacting parts SS 316, SS 316Ti, Novapress *
Ready for operation after 1 hr
Heater temperature adjustable +100 to +200 °C * optional -PT100 with PT100-sensor, without thermostat
Power supply 230V 50Hz / 240V 60 Hz, 315W optional 115V 60Hz 300W
Electrical connection terminals max 4 mm
2
, 1x PG13,5 cable gland
Degree of protection / Electrical equipment stan-
dard
IP54, EN 60529 / EN 61010, EN 60519-1
Weight 4 kg
Technical Data
* Standard
** In case of higher ambient temperatures use option PT100 (Part No. 20S9025) or thermocouple Fe-CuNi respectively Ni-CrNi (Part No. 20S9027 resp. 20S9028) instead of the thermo-
state controller. Then, an additional electronic temperature controller (see data sheet 2-5.1) is necessary.
∆P at flow of: 100 200 500 1000 2000 Nl/hr
∆P pressure loss with new filter element
ø 46 x 225 mm - V10, V10-0, V10/HC, V10-0/HC
<3 <5 <20 <30 <40 mbar
∆P pressure loss with new filter element
ø60 x 550 mm - V10-1, V10-2, V10-1/HC, V10-2/HC
<1 <1 <2 <10 <20 mbar
Order example:
M&C sample probe SP 10-H with stainless steel large surface filter incl. internal volume displacer and extension tube incl. internal volume displacer, overall
length 1metre, with over temperature protection and low temperature alarm and weather protection shield.
SP 10-H (Part No.01S2000); V10-1 (Part No.01S9400); extension tube Vm 500 mm (Part No.01S9010) for a total probe length of 1m; TA +; TA -; weather protection
shield130 (Part No.01S9200).
Available options: type Part No.
SS316 Filter without volume displacer ø 46 x 225 mm, max. 600 °C, up to 10 g/m3 dust content -V10 standard
SS316 Filter with volume displacer ø 46 x 225 mm, max. 600 °C, up to 10 g/m3 dust content -V10-0 on request
Hastelloy Filter without volume displacer ø 46 x 225 mm, max. 900 °C, up to 10 g/m3 dust content -V10/HC 01S9500
Hastelloy Filter with volume displacer ø 46 x 225 mm, max. 900 °C, up to 10 g/m3 dust content -V10-0/HC 01S9520
SS316 Filter without volume displacer ø 60 x 550 mm, max. 600 °C, above 10 g/m3 dust content -V10-2 01S9405
SS316 Filter with volume displacer ø 60 x 550 mm, max. 600 °C, above 10 g/m3 dust content -V10-1 01S9400
Hastelloy Filter without volume displacer ø 60 x 550 mm, max. 900 °C, above 10 g/m3 dust content -V10-2/HC on request
Hastelloy Filter with volume displacer ø 60 x 550 mm, max. 900 °C, above 10 g/m3 dust content -V10-1/HC on request
SS316Ti extension tube without volume displacer, 500 mm -Vo 01S9000
Additional 500mm SS316Ti extension tube without volume displacer, for an overall length up to 2 m
-Vo+ 01S9005
SS316Ti extension tube with volume displacer, 500 mm -Vm 01S9010
Additional 500mm SS316Ti extension tube with volume displacer, for an overall length up to 2 m
-Vm+ 01S9015
Hastelloy extension tube without volume displacer, 500 mm -VoHC 01S9510
Additional 500mm Hastelloy extension tube without volume displacer, or an overall length up to 1,5 m
-VoHC+
01S9515
Hastelloy extension tube with volume displacer additional 500 mm -VmHC 01S9525
Additional 500mm Hastelloy extension tube with volume displacer, for an overall length up to 1,5 m
-VmHC+ 01S9530
Personal and weather protection shield out of stainless steel for probe SP10 with standard flange DN65 -130 01S9200
Stainless Steel 316Ti - shape protection plate, for filter V10 and V10-0 -AB-SS 01S9100
Stainless Steel 316Ti - shape protection plate, for filter V10-1 and V10-2
-AB1-SS 01S9105
Mounting flange in alternative formats: DN... PN... or ANSI... lbs.... -So on request
Power 115V 60Hz -115V 02S9035
Low temperature alarm, 100-180 °C adjustable -TA - on request
Over temperature protection with reset key, setting a 220 °C -TA + on request
>5 bar g operating pressure version -P on request